How We Engineered a 10-Ton Outdoor LED Screen Structure for Thailand Customer

Thailand event production company needed to hang a 10-ton outdoor LED wall over a stadium-scale show site, with two hard requirements written into the brief: the support structure had to be designed for a load of approximately 15 tons, and it had to pass a wind resistance test. The heavy duty LED wall truss solution our engineering team delivered is built from national-standard Q355B carbon steel, uses 100 × 100 × 5 mm square tube for the main and secondary chords, 60 × 60 × 5 mm square tube for the diagonal braces, and a 48.3 × 3.2 mm round tube access face. Its defining features are double-row columns tied together by an I-beam base with counterweights, frame panels between the column rows, rear tie-back rods, and front diagonal supports. This article sets out the complete design logic, the material schedule, and the engineering reasons this configuration holds a 10-ton screen safely.

page-800-385

Figure 1

The 3D design drawing supplied to the Thailand customer: paired column towers, an I-beam base under each pair, frame panels between the rows, rear tie-back rods and front diagonal supports.

 

Project Overview: What the Thailand Customer Needed

 

page-1280-960

The customer is an event and production contractor in Thailand working on a large outdoor LED wall installation. The screen itself weighs 10 tons, and in use it sits on the front face of the support structure, fully exposed to the weather. That combination - a very heavy suspended mass plus a large exposed surface area - is the reason the brief was so strict.

Three requirements shaped the design. First, the structure had to support the 10-ton screen with margin, so the team set the design load capacity at approximately 15 tons, equivalent to a 1.5× safety factor over the working load. Second, the system had to pass a wind resistance test, because an outdoor LED wall behaves like a sail and wind can become the governing load case rather than the screen weight. Third, the structure had to be practical to build and operate on a real event site, including access for technicians to inspect the screen and hang lighting and rigging equipment.

The brief was answered with a purpose-built, double-row steel structure rather than an off-the-shelf ground support truss. The design was produced as a full 3D model, then fabricated, shipped and erected on site. Figures 1 and 2 below show the two ends of that process: the design drawing and the completed structure.

page-1280-960

Why a 10-Ton LED Screen Needs Purpose-Built Heavy Duty LED Wall Truss Solutions

 

A 10-ton screen is not a load you hang from a generic single-row ground support truss. Once a screen reaches this weight and this wind-exposed area, the structure stops behaving like a simple vertical support and starts behaving like a small building that must resist overturning.

Four load effects have to be resolved together:

Dead load

The 10 tons of screen plus the self-weight of the truss, top beams and rigging hardware.

Forward tilt moment

The screen hangs on the front face, so its weight acts at an offset from the column axis and continuously tries to tip the structure forward.

Wind load

A large outdoor LED wall presents a large sail area. Wind pushes horizontally on the screen and the truss, generating overturning moment, uplift on the windward and leeward supports, and horizontal shear at the base.

Dynamic and installation loads

Rigging operations, screen installation, and wind gusts acting on a partially deployed screen.

The short answer to "why not a standard ground support truss" is that a standard system is sized for the vertical load and relies on a single line of columns plus ballast. It has very little capacity to resist a sustained forward tilt moment combined with wind. The heavier and more exposed the screen, the more the design has to shift weight away from the front of the structure - which is exactly what the double-row configuration does.

 

Design aspect

Standard single-row ground support truss

This heavy duty LED wall truss solution

Column layout

One line of columns

Double-row (paired) columns

Tilt resistance

Limited; relies on ballast mass alone

I-beam base couples both rows, creating a wide resisting lever arm; front diagonal supports carry the tilt force to the ground

Base system

Individual base plates with ballast

Continuous I-beam base connecting both column rows, with counterweights on top

Lateral stability

Depends on guying

Rigid frame panels between the column rows tie them into a braced box

Rear anchoring

Optional

Rear tie-back rods anchor the top of the structure and resist forward rotation and uplift

Technician access

Separate access needed

One face built from 48.3 × 3.2 mm round tube as a climbable access face

Typical use

Light to medium loads, short spans

10-ton-class outdoor LED walls, stadium and festival sites, high wind exposure

 

Structural Design Overview: Double-Row Columns, I-Beam Base and Frame Panels

 

The core idea of this design is redundancy. No single element is expected to carry the entire 10-ton load and the associated tilt moment on its own; instead, the load is distributed through several cooperating systems, so that if one load path is reduced, the others continue to hold the structure.

 

The structure is built as a series of paired column towers. Each pair consists of two parallel steel columns - the double-row arrangement - that stand a short distance apart. At the base, the two rows are joined by a heavy I-beam base, which acts as a rigid transverse beam under the pair. Counterweights are placed on those bases. Higher up, the two rows of each pair are connected by frame panels, which are braced frames spanning between the inner faces of the columns. At the top, the towers are linked by primary steel beams that carry the hanging points for the screen. Finally, rear tie-back rods run from the upper part of the structure down and back to ground anchors, while front diagonal supports run from beneath the front columns out to the ground in front of the structure.

 

Viewed as a whole, the arrangement works like this: the double columns and the I-beam base form a stable portal in the transverse direction; the frame panels, tie-back rods and diagonal supports stiffen it in the longitudinal direction; and the counterweights plus the tie-downs keep everything seated during an overturning event. That is the structural logic that lets the same system carry a 10-ton screen and still pass a wind resistance test.

 

Material Specification: Q355B National-Standard Carbon Steel

 

All steel used in this LED wall truss is national-standard carbon steel Q355B - the structural steel grade specified in the Chinese national standard GB/T 1591, with a minimum yield strength of 355 MPa for the common thickness range and good weldability and low-temperature toughness. For a heavy duty application this matters more than the tube dimensions: Q355B keeps the sections compact while still delivering the strength required to hold a 10-ton screen under wind load, and it is a weldable grade that allows full welded joints and reliable pin connections.

 

The tube schedule for this project is deliberately simple and consistent, which makes fabrication quality easier to control and spare parts easier to source:

Element

Section

Notes

Main chords (columns and top beams)

100 × 100 × 5 mm square tube

Primary load-carrying member of each tower and beam

Secondary chords

100 × 100 × 5 mm square tube

Matched to the main chords so the lattice stays uniform

Diagonal braces

60 × 60 × 5 mm square tube

Lattice web transferring shear between chords

Access face

48.3 × 3.2 mm round tube

One full face of the structure, built for climbing access

Base connection

Heavy I-beam

Connects the two column rows of each pair and carries counterweights

 

Using the same 100 × 100 × 5 mm section for both the main and secondary chords is a deliberate choice. It removes the need to distinguish between two similar square tubes on site, keeps the lattice geometry identical from tower to tower, and means the fabrication jigs and connection details stay the same across the whole structure. The thicker 5 mm wall on the 60 × 60 mm brace tube, relative to typical lightweight truss practice, adds shear capacity exactly where the double-row braced panels transfer load between the column rows.

 

How the Structure Resists the Forward Tilt Force of the Screen

 

The most important single design problem on this project is the forward tilt force. A 10-ton screen hanging on the front face of the structure is an eccentric load: its weight does not act down the axis of the columns, it acts well in front of them. The result is a continuous moment that tries to rotate the entire structure forward, and if that moment is not resisted, the structure folds toward the audience.

Five features work together to resist it:

1

I-beam base. Connecting the two column rows of each pair with a heavy I-beam base is the primary measure. Instead of two independent columns that each tip forward individually, the base turns each pair into a portal frame. The forward tilt of the front row is transferred through the I-beam into the rear row, which is loaded in compression against the ground. This is the reason the double-row layout exists: the lever arm between the two rows converts the tilt moment into a much smaller push–pull couple.

2

Counterweights on the base. Mass placed on the I-beam bases increases the restoring moment directly. Because the weights sit behind the front row (and on a base that spans both rows), they resist overturning rather than adding to the forward eccentricity.

3

Front diagonal supports. Diagonal supports running from beneath the front columns down to the ground in front of the structure give the tilt force a direct, short load path into the ground, bypassing the base connection entirely. This is why the diagonal supports are described as preventing the forward tilt of the screen.

4

Frame panels between the rows. The braced frames connecting the two column rows prevent the rows from separating, twisting or buckling independently under a one-sided load, holding the portal geometry rigid.

5

Rear tie-back rods. The tie-back rods anchor the top of the structure backwards, resisting forward rotation at its most effective point - the top - and simultaneously resisting the uplift that wind generates on the leeward side.

The net effect is that the 10-ton screen load is resolved through multiple, mutually supporting load paths rather than a single critical connection.

 

The 48.3 × 3.2 mm Round Tube Face: Built-In Access for Inspection and Rigging

 

One face of the structure is built from 48.3 × 3.2 mm round tube instead of the 100 × 100 mm square tube used elsewhere. This is not a fabrication shortcut - it is a deliberate functional design feature, and its purpose is access.

 

At this scale, maintenance is not optional. A 10-ton outdoor LED screen needs regular inspection, module replacement, cable work, and the addition of lighting or rigging equipment. Without a dedicated access route, technicians would have to bring in separate access towers or scaffolding, which costs time and money on every event and adds another structure to engineer against wind.

 

By building one entire face of the truss as 48.3 × 3.2 mm round tube, the structure provides its own fixed ladder. Round tube works well in this role: the circular section gives a consistent, easily gripped rung geometry, it has no sharp corners to damage ropes, slings or working-at-height equipment, and standard clamps and couplers fit it directly. The 3.2 mm wall thickness keeps the access face light without making it fragile, and the arrangement keeps the truss section structurally continuous - the access face is part of the load-carrying lattice, not an add-on.

 

The practical benefit for the customer is that screen inspection and equipment hanging can be carried out from the structure itself, using the same face that is already engineered into the wind load calculation.

 

Wind Resistance: How This LED Wall Truss Meets the Wind Load Test

 

For an outdoor LED wall, wind is often the governing design load, not the 10-ton screen weight. A large LED wall presents a substantial sail area at height, and the resulting wind pressure produces horizontal thrust, overturning moment and differential uplift between the windward and leeward supports. Because the empty truss has a much smaller exposed area than the deployed screen, the structure has to be checked in both states: with the screen deployed, and with the screen removed or retracted.

  • Wind load verification follows established wind loading practice - wind actions according to EN 1991-1-4 (Eurocode 1) and ASCE/SEI 7 for the wind pressure calculation, applied in combination with self-weight and suspension loads, with temporary-event-structure practice such as ANSI E1.21 (referenced by the International Fire Code for temporary special event structures) informing the operational wind management approach. The calculation covers:
  • Wind load, self-weight and screen suspension load as a combined load case, not as separate checks.
  • Overturning, sliding and uplift at the base, verified against the restoring effect of the counterweights, the double-row portal action and the tie-back rods.
  • Allowable uniformly distributed and concentrated suspension loads at the actual span used on site.

A maximum permissible wind speed, above which the screen must be lowered or the structure de-ballasted and dismantled.

The design measures that carry this verification are the same ones that resist the tilt force: mass and counterweights, a wide double-row base, braced frame panels, tie-back rods and diagonals, and modular pin connections that keep load transfer concentric. The verification output is supplied to the customer as a structural document that can be submitted for event approval and used as the basis of the wind resistance test.

 

From 3D Design to the Completed Thailand Site

 

The project followed a design-then-build sequence. The engineering team first produced a complete 3D model of the structure - the drawing shown in Figure 1 - including the paired column towers, the I-beam bases, the frame panels between the rows, the rear tie-back rods and the front diagonal supports. The 3D stage is where the load paths are resolved: base positions, counterweight layout and the geometry of the diagonal and tie-back members are fixed before any steel is cut.

 

Fabrication followed the drawing, with the tube schedule described above, then the structure was packed in modular sections for shipment to Thailand. On site the build sequence runs from the ground up: the I-beam bases are positioned and counterweights placed, the first sections of both column rows in each pair are assembled onto the bases, the frame panels are fitted between the rows, then the remaining column sections are built up, followed by the top beams. The rear tie-back rods and the front diagonal supports are installed and tensioned before the screen is hung.

page-2331-1602

Figure 2

The completed structure on site in Thailand. The double-row column towers, I-beam bases with counterweights, frame panels and top beams match the design drawing in Figure 1; the LED screen is rigged on the right-hand bay.

 

Figure 2 shows the finished installation. The paired columns and the bases sitting on the stadium floor are clearly visible, along with the green pitch and the tiered seating behind the structure. Comparing Figure 2 with Figure 1 shows the erected structure matching the 3D design, which is the practical confirmation that the intended load path - double rows, coupled bases, braced panels, tie-back rods and diagonals - is the one that was actually built.

 

Key Technical Specifications at a Glance

 

Parameter

Specification

Application

Heavy duty LED wall truss solution for outdoor LED screen suspension (stadium, concert, festival sites)

Screen weight

10 tons

Design load capacity

Approximately 15 tons (1.5× safety factor over the working load)

Steel grade

Q355B national-standard carbon steel

Main chords

100 × 100 × 5 mm square tube

Secondary chords

100 × 100 × 5 mm square tube

Diagonal braces

60 × 60 × 5 mm square tube

Access face

48.3 × 3.2 mm round tube (one full face, for inspection and rigging access)

Column configuration

Double-row (paired) columns per tower

Base system

Heavy I-beam base connecting both column rows, with counterweights

Bracing

Frame panels between column rows, rear tie-back rods, front diagonal supports

Wind resistance

Verified against wind load test (wind + self-weight + suspension load combination)

Engineering documents

Structural calculation and load test documentation available for event approval

Customization

Sections and spans produced to project drawings

 

FAQ: Heavy Duty LED Wall Truss Solutions

 

Q: What is a heavy duty LED wall truss solution?

A: It is a purpose-designed steel support structure for suspending very large outdoor LED screens - in this case a 10-ton wall - where the design must resist not only the screen's weight but also the forward tilt moment created by an eccentrically hung screen and the wind load acting on a large exposed surface.

Q: How much load can this LED wall truss carry?

A: The structure was designed for a load capacity of approximately 15 tons, supporting a 10-ton LED screen - a 1.5× safety factor over the working load. Load capacity is always tied to a specific configuration and span, so for a different screen size the allowable uniformly distributed and concentrated suspension loads are recalculated for that span.

Q: Why use double-row columns instead of a single-row ground support truss?

A: Because the screen hangs on the front face, its weight acts at an offset from the columns and produces a constant forward tilt force. Two parallel rows of columns, coupled at the base by an I-beam, turn that tilt force into a push–pull couple across a wide lever arm instead of letting each column tip forward on its own.

Q: What steel is used, and why Q355B?

A: The complete truss uses national-standard Q355B carbon steel - a 355 MPa minimum yield strength structural grade with good weldability and low-temperature toughness. It lets the structure hold a 10-ton screen under wind load with compact 100 × 100 × 5 mm sections rather than much heavier profiles.

Q: What is the 48.3 × 3.2 mm round tube face for?

A: It is a built-in access face. One full face of the structure is made from 48.3 × 3.2 mm round tube so technicians can climb the structure to inspect the LED screen and hang lighting and rigging equipment, without bringing separate access towers to site on every event.

Q: How does the structure pass the wind resistance test?

A: Wind load is calculated together with self-weight and screen suspension load as a combined case, following established wind loading practice (EN 1991-1-4, ASCE/SEI 7 and temporary event structure practice such as ANSI E1.21). Overturning and uplift are resisted by the counterweights on the I-beam bases, the double-row portal action, the braced frame panels, the rear tie-back rods and the front diagonal supports, and the design defines the maximum wind speed above which the screen must be lowered.

Q: Can the truss be customized for a different screen size or venue?

A: Yes. The section dimensions, tower heights and spans are produced to project drawings. Standard sections are modular and pin-connected for transport and repeated assembly, and the engineering team recalculates the allowable loads, base counterweight plan and tie-back layout for each project.

Q: Do you provide installation support and documents for approval?

A: Yes. As an original manufacturer with an in-house engineering team, we supply the structural solution from 3D design through fabrication, plus on-line technical briefings for the customer's engineers and the option to dispatch our own team for on-site roof and structure assembly on large projects. Structural verification documents and load test reports are issued per project so the customer can submit them for event approval.

 

Working With Us on Your Next LED Wall Truss Project

 

This Thailand project shows what a heavy duty LED wall truss solution involves when the brief is taken seriously: a design load set above the working load, a material grade chosen for the actual stress, a base system engineered for the tilt moment rather than just the vertical load, a braced double-row structure verified against wind, and built-in access so the screen can be maintained.

If you are planning an outdoor LED wall, send us the screen weight and dimensions, the venue and site conditions, and the wind requirement your local authority or client needs to see. Our engineering team will return a 3D design with the matching tube schedule, base and counterweight plan, and the structural calculations needed for approval.

For reference, project videos from our stage and roof structures are available at: https://www.youtube.com/@shizhangroup